AE-087

Technical Information

Substrate Fire-rated plasterboard ceiling (min. one layer of 13mm plasterboard or greater)
Service range 1-3 x Pair PE/FR + 1-3 x 25mm uPVC pipe + 1-3 x TPS cables
Annular gap 3.5mm - 20mm
AGNI-Products AGNI-Seal, AGNI-Wrap 50, AGNI-Clips, AGNI-Strap
Protection installation Asymmetrical – installed on the fire side only

 

Compliance Information

Standards AS1530.4-2014, AS4072.1-2005
FRR/FRL -/30/30 in the ceiling with FRR 30/30/30

-/60/60 in the ceiling with FRR 60/60/60

Reference PF24079

Documents

Download Installation InstructionsDownload RIRF24079

Products Used in This System

AGNI-Wrap®

Learn More
agni-wrap

AGNI-Straps®

Learn More

AGNI-Clips®

Learn More

AGNI-Seal®

Learn More
agni-seal
Designed and developed by Maxim Seryakov